Made by Cummins® Cummins commercial diesel generator sets integrate the universal design, production and testing standard of Cummins, providing fully reliable and integrated power generation systems with optimum performance for applications in Standby power, Prime Power and Continuous operation.
In accordance with the standard of ISO8528-2005 and GB/T2820-2009 AC Generator Sets Driven by Reciprocating Internal Combustion Engine.
Certified to ISO9001 and ISO9002 for generator set design and manufacture.
Cummins provides full quality assurance and is responsible for the warranty of generator sets including engine, alternator and control system.
National specialized service network ensures
24 hours after-sale service and the supply of parts and accessories.
Model Portfolio Table
Genset Model |
Standby power |
Prime power |
Engine |
Alternator |
Control system |
||
Kva |
Kw |
Kva |
Kw |
||||
C700D5 |
700 |
565 |
640 |
512 |
VTA28-G5 |
S5L1D-F41 |
PC1.2 |
Ratings definitions:
Emergency Standby Power (ESP):
Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. Emergency Standby Power (ESP) is in accordance with GB.T2820/ISO 8528. The effective oil limited power is in
accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.
Electrical Performance
Prime Power (PRP):
Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with GB.T2820/ISO 8528. A 10% overload capability is available
in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.
Limited-Time Running Power (LTP):
Applicable for supplying power to a constant electrical load for limited hours. Limited-Time Running Power (LTP) is in accordance with GB.T2820/ISO 8528.
Base Load (Continuous) Power (COP):
Applicable for supplying power continuously to a constant electrical load for unlimited hours. Continuous Power (COP) is in accordance with GB.T2820/ISO 8528, ISO 3046,
AS 2789, DIN 6271 and BS 5514.
Cummins Power Generation C700D5 Diesel Generator Set specifications:
Voltage regulation (no load to full load) |
±1% |
Steady-state voltage variation |
±1% |
Frequency regulation (no load to full load) |
1.40% |
Steady-state frequency variation |
±0.25% |
EMC compatibility |
BS EN61000-6-4 /BS EN61000-6-2 |
Fuel consumption (L/hr) @ 100% load |
140 |
Total coolant capacity (engine and water tank), L |
180 |
Bottom oil tank capacity, L |
83 |
Outline
Model |
A |
B |
C |
Weight |
mm |
mm |
mm |
(kg) |
|
C700D5 |
3934 |
1468 |
2179 |
5839 |